WHY?

Ground bond test (also referred to as PE  resistance test, ground continuity test) determines whether the safety ground circuit of the Device Under Test (DUT) can adequately handle fault current if the product should ever become defective. The measured resistance has to be lower than the indicated limit from the applicable international standards. Usual values are << 500mΩ.

Quanti’s ground bond is a high current continuity test. Ground continuity is important for instance in manufacturing to ensure that the products leaving to the customers are safely grounded.

Output current range 3 - 30A AC

With Quanti’s ground bond test you will test with the currents that most common standards require. User programmable output current from 3A to 30A AC provides extensive coverage for testing according to UL, IEC, EN and other requirements.

Output current resolution 0.01A

Adjustable output current and milliohm trip ranges to meet all safety specifications for ground bond test requirements.

Programmable High and low resistance limits

A resistance measurement range from 0.5mΩ to 500mΩ, in conjunction with user-programmable high and low resistance limits with Pass/Fail indication, makes this tester ideal for production testing.

4 wire measurement, constanctly accurate results

4 wire measurement ensures accurate and repeatable measurements. When measuring low values resistances, an important error source can be found in the contact resistance. In many applications, the contact resistance value can go beyond the value which has to be measured. To cancel this error source, a 4 wire measurement is used.

For instance during the day the factory ambient temperature can change, which would mean wrong resistance values with 2 wire measurements if the error is not manually and constantly offset.

Ground Bond function specifications

Output current

Range: 3.00 - 30.000A AC
Resolution: 0.01A
Accuracy: ± 1% (of setting + 0.15A)
Output Frequency

50 / 60Hz, User selectable
Resistance measurement

Range: 0.5mΩ - 500.0mΩ
Resolution: 0.1mΩ
Accuracy: 0.5% of range
Test method

4 wire measurement
Test time

0; 0.3 - 999.9sesc (0 = continuous)
HI and LO limit

Range: 0.5mΩ - 500.0mΩ
Resolution: 0,1mΩ
Maximum loading

20A 500mΩ
25A 380mΩ
30A 300mΩ
Current display

Range: 3.00A - 30.00A
Resolution: 0.01A
Accuracy: ± (1% of reading + 0.15A)
Waveform

True Sine wave